Full Wiring 3 — FRONT-board I/O + RS485 panel

wheel / pinch = zoom · drag = pan
SHEET 3: FRONT BOARD I/O AND DASH PANEL (DRAFT) Front Waveshare ESP32-S3-POE-ETH-8DI-8DO · 12V fed, not PoE · yellow pins are new or reassigned on this revision FRONT BOARD always on · RS485 master · Ethernet DIs opto-isolated 5-36V · DOs 500mA open-drain sinks, built-in flyback DI1 Door O1 SET DO1 DI2 Ignition O2 accessories DO2 DI3 Reverse O3 PC power pulse DO3 DI4 Dash button O4 camera tier DO4 DI5 Cab temp O1 RESET DO5 DI6 Alternator temp DC-DC enable DO6 DI7 O1 read-back SPARE DO7 DI8 Shore present SPARE DO8 INPUTS 22 AWG · every 12V tap fused at the tap dome-light tap, 1A fuse add-a-fuse tap, 1A fuse reverse-lamp tap, 1A fuse dry contact to GND SENSOR TYPE TBD NC thermal switch, open = hot D-151 pole Y (Sy) 120V-coil relay, dry contact Door Ignition Reverse Dash button Cab temp sensor Alternator temp sensor O1 read-back Shore present D-151 S, 300ms low = ON D-151 latching, S RLY-O2 pin 85 RLY-O2, Sheet 2 OptiPlex PWR header OptiPlex PWR header, Sheet 5 RLY-O4 pin 85 RLY-O4, Sheet 2 D-151 R, 300ms low = CUT D-151 latching, R RLY-DC pin 85 RLY-DC, Sheet 2 F12 3A, always-on 12V 18 AWG, Sheet 2 GND + DI COM front - bus Switch A Cat5e, data only ONE Cat5 home run, box to panel pair 1 RS485 A/B · pair 2 12V + GND, 1-2A fuse at the box 120 ohm only at the two bus ends DASH PANEL, behind the switches MODBUS IO 8CH (SKU 26244) RS485 slave, addr 2 8 isolated DI, 8 DO sinks (ULN2803A) last device on the bus: 120R jumper on DI 1 Rock switch, DI 2 Fog switch M-DO1-6 to relay coils, Sheet 2 DMWD switches SW1 ROCK, SW2 FOG NO to module DI, COM to GND LED+ to 12V rail LED- to module DO: sink = ON built-in LED resistor Analog in 8CH (optional) addr 3, same 2 wires AI1 air tank 4-20mA logging alternator temp could go here DI sense read-back DO sink RS485 12V GND LED drive NEW PINS (review these) DO5: O1 needs 2 pins, old list counted 1. DO6: DC-DC enable, through RLY-DC. DI6: alternator thermal switch, normally closed, so a broken wire reads hot. DI8: shore relay, 120V coil at the charger. RPM: OptiPlex reads CAN, sends it by MQTT. No RPM for 10s = DC-DC off. CONFIRM DI5 cab temp: an isolated DI only reads on/off. Use a thermostat switch, or move it to the analog module. DI6 trip temperature TBD. DC-DC D+: confirm on the unit, and test that D+ off stops it at 14V input. Buttons: multi-click and hold on native DI. Simple on/off on the Modbus module, it polls every 100-300ms. Debounce all in ESPHome.

open the PDF version ›

‹ prevnext ›